The whole envelope, in one specification.
Glazing, opaque structure and retrofit — three systems from one engineering team. Every level below carries its nominal thickness, its areal density and the standard it is classified to, so it can go straight into a glazing schedule or a door and wall specification.
Three systems. One decision.
BTP Ballistic Glazing — BR2 to BR7
A layered composite of laminated safety glass, polycarbonate, acrylic (PMMA) and selected PET, engineered to absorb and disperse projectile energy while holding optical clarity. Weights are per square metre — the number your frame, lintel and ironmongery have to carry.
| Product | Classification | Test round | Composite | Thickness | Areal density |
|---|---|---|---|---|---|
| BTP-1 | BR2 | 9 × 19 mm Luger | Laminated glass + polycarbonate + PET | 11 mm | 27.5 kg/m² |
| BTP-2 | BR3 | .357 Magnum | Laminated glass + PET | 13 mm | 32.5 kg/m² |
| BTP-3 | BR4 | .44 Magnum | Laminated glass + PET | 15 mm | 37.5 kg/m² |
| BTP-L-4 | BR3 lightweight | .357 Magnum | 2 polymers + PET — portable, self-adhesive | 14 mm | 16.7 kg/m² |
| BTP-L-4 | BR4 lightweight | .44 Magnum | 2 polymers + PET — portable, self-adhesive | 16 mm | 19 kg/m² |
| BTP-5 | BR5 | 7.62 × 39 · 5.56 × 45 mm | Laminated glass + polycarbonate + PET | 25 mm | 49.7 kg/m² |
| BTP-6 | BR6 | 7.62 × 51 mm | Laminated glass + PET | 29 mm | 55 kg/m² |
| BTP-7 | BR7 | 7.62 × 54R mm API | Laminated glass + PET | 37 mm | 77 kg/m² |
| Other BR levels, curved glazing and non-standard geometry — on request. | |||||
Areal density stated per m² of glazing. Classification to EN 1063; EN 1522 applies to the complete window, door or shutter assembly including frame. The inner face carries a BoPET spall-control layer. Classifications apply to the complete tested Fortis system.
BNTP Opaque Armour Panels — FB1 to FB7
Glazing is rarely the weak point — the wall beside it usually is. BNTP panels are UHMWPE laminates, optionally with a silicon carbide ceramic strike face, built into structural walls, safe-room linings, door leaves and window and door frames.
| Product | Classification | Test round | Composite | Thickness | Areal density |
|---|---|---|---|---|---|
| BNTP-1 | FB1 – FB4 | All handguns | UHMWPE + PET | 8 mm | 7.44 kg/m² |
| BNTP-2 | FB5 | 7.62 × 39 mm FMJ · 5.56 × 45 mm · .223 Rem | UHMWPE + PET | 16 mm | 14.8 kg/m² |
| BNTP-3 | FB6 · VPAM 6 · STANAG L1 | Rifle, ball | UHMWPE + SiC ceramic + PET | 16 mm | 33 kg/m² |
| BNTP-4 | FB7 · VPAM 7 · STANAG L2 | Rifle, hard core | UHMWPE + SiC ceramic + PET | 18 mm | 34.9 kg/m² |
| BNTP-5 | FB7 · VPAM 7 · STANAG L2 | Rifle, hard core | Ballistic steel + UHMWPE | 21 mm | 55.4 kg/m² |
| Higher levels — NATO STANAG Level 3, VPAM 8, FB8 — on request. | |||||
FTL 300 & FTL 600 Security Laminate
The same high-tensile PET laminate we build into the certified ballistic glazing above, supplied as a bonded retrofit on the glass already in the building. Under 1 mm added. No change to the pane, the frame or the structural opening — which is why it does not touch the glazing schedule at all.
Scope, stated plainly: FTL is an anti-break-in and anti-vandal product. It is not classified ballistic glazing and must not be specified against a ballistic requirement. Where the brief calls for a BR level, specify BTP. EN 356 classification is in progress.
| Optical property | FTL 300 | FTL 600 | Method |
|---|---|---|---|
| Thickness | 300 µ / 12 mil | 600 µ / 24 mil | GB/T 29061 |
| Visible light transmittance | 89 ± 3 % | 92 ± 3 % | GB/T 2680 |
| Clarity | ≥ 99 % | ≥ 99 % | ASTM D1003 |
| Haze / fog degree | ≤ 3.5 % | ≤ 3.5 % | ASTM D1003 |
| UV blocking | ≥ 25 % | ≥ 99 % | GB/T 2680 |
| Total solar energy rejection | 13 ± 2 % | 14 ± 2 % | GB/T 2680 |
| Aging — UV, 1,200 h | No change | No change | 0.5 W/m² @ 340 nm |
Roll dimensions 1.52 m × 45 m, self-adhesive. Installed exclusively by certified Fortis technicians. Full FTL product page, reflection and IR data →
What the frame actually carries.
Areal density is the figure that decides whether an opening can be upgraded at all. Unit weight for three common pane sizes, so the answer is available before the structural engineer is.
| System | 1.2 × 2.2 m 2.64 m² |
1.5 × 2.4 m 3.60 m² |
1.8 × 3.0 m 5.40 m² |
|---|---|---|---|
| BTP-3 — BR4 · 37.5 kg/m² | 99 kg | 135 kg | 203 kg |
| BTP-5 — BR5 · 49.7 kg/m² | 131 kg | 179 kg | 268 kg |
| BTP-6 — BR6 · 55 kg/m² | 145 kg | 198 kg | 297 kg |
| BTP-7 — BR7 · 77 kg/m² | 203 kg | 277 kg | 416 kg |
| FTL 600 retrofit | Under 1 mm added — no meaningful change to dead load, frame or opening. | ||
Glazing weight only, rounded to the nearest kilogram. Excludes frame, gaskets and fixings. Confirm hinge, hardware and lintel capacity with the structural engineer before issuing for construction.
Clause text. Copy it into the schedule.
Written to drop into a specification with the level swapped for the one the threat assessment calls for. Send us the drawing set and we will return it marked up, at no cost.
From drawing set to certificate.
Send the drawing set. We'll mark it up.
System, level and build-up called out per opening, with areal density for the structural check and the full test documentation. No cost, no obligation — we would rather be specified correctly than specified often.